John Temple
John Prohonic
Product Development
Summary : Properly Designed Washer Decontaminators Washer Disinfectors are designed to clean all surfaces thoroughly, thereby providing the critical prerequisite for the safe handling, disinfecting, and the sterilizing of surgical instruments.
Critical cleaners, usually referred to as Washer Decontaminators Washer Disinfectors, perform pre-wash, ultrasonic (optional), detergent washing, purified water elevated temperature rinsing, lubrication and high temperature drying in such a manner as to provide thoroughly clean, stain free and lubricated medical devices. Surgical Instruments cannot be sterilized (be sterile) unless all exposed surfaces are properly cleaned, prior to sterilization, to remove soil (debris, bioburden) and properly rinsed to prevent staining.1,2,3 Not all Washer Decontaminators Washer Disinfectors provide adequate pre-rinsing, pre-cleaning, purified water rinsing, and thereby render higher rejection rates of processed surgical instruments. 4,5.
Surgical Instrument Washer using an Ultrasonic Cleaner Solution
Proper Washer Decontaminator Washer Disinfector Design Secures Performance
The proper sequence of treatment and the correct choice of time, temperature and the components used are necessary to render surgical instruments that are critically clean, safe to handle, and have the prerequisite for sterilization. 6,7,8.
Surgical Instrument Washer using an Ultrasonic Cleaner Solution
Washer Decontaminators Washer Disinfectors employ a cold water pre-wash to remove gross debris. This removes proteins and lipids, preventing them from being baked onto devices during the high temperature treatments to follow. 9, 10. Then, the ultrasonic process creates millions of micro implosions to loosen and free debris from lock boxes, hinge pins, serrations and other difficult-to-access surface areas.
The Washer Decontaminators Washer Disinfectors detergent wash then applies high flow low pressure water with a cleaning concentrate (at ~ 135 degrees F) in such a manner as to evenly reach all areas of the load and strip bioburden from the surgical instruments. The elevated temperature (at ~ 194 to 209 degrees F) purified water final rinse secures the biocidal process, removes mineral deposits from prior cycles and lubricates the instruments. The high temperature (at ~ 158 to 230 degrees F) dry cycle presents heated, forced air which dries each device. The critical cleaned medical devices are now clean, safe to handle, have the prerequisite for sterilization, and are properly prepared for further reprocessing.
Washer Decontaminator Washer Disinfector - Complete Removal of Pathogens
The Washington University School of Medicine at Washington University Medical Center examined the performance of a properly designed Washer Decontaminator Washer Disinfector (CESCO washer Decontaminator Model 520) and found that it removed all organisms from the surgical instruments tested. 11
Surgical Instrument Washer using an Ultrasonic Cleaner Solution
The Washer Decontaminator Washer Disinfector was tested for its ability to complete remove pathological organism from surgical instruments.
Pure cultures of the following organisms were grown on appropriate agar plates:
1. Staphylococcus aureus;
2. Pseudomonas aerations;
3. Escherichia coli;
4. Bacillus species
Kelly clamps, tweezers and scissors wee placed on these plates of organism, taking care to ensure that all serrated edges were packed with all the organisms. Each contaminated instrument was then dipped into the tube of Thiogycolate medium before being placed in all the washer baskets. The instruments were then processed through the complete Washer Decontaminator Washer Disinfector cycle. At the end of the drying cycle, the instruments were allowed to cool and then dipped into another tube of Thioglycolate medium.
Surgical Instrument Washer using an Ultrasonic Cleaner Solution
Results
All tubes of the Thioglycoate medium tested before the wash grew the appropriate organism within six to 18 ours after testing. All tubes tested at the end of the wash showed no growth after 14 days of incubation. This Washer Decontaminator Washer Disinfector removed all organisms from the instruments.
Washer Decontaminator Washer Disinfector Efficacy of Disinfection 100%
Another evaluation of Washer Decontaminators Washer Disinfectors confirmed that the efficacy of disinfection was 100%. In this study, L.P. Jette and N.G. Lambert used two test methods.12 One method (N) was to test the effect of heat only within the disinfection process and the other test method (G) was to test the efficacy of both heat and washing. Each method gave reproducible results and confirmed the efficacy of the Washer Decontaminator Washer Disinfector.
Surgical Instrument Washer using an Ultrasonic Cleaner Solution
Washer Decontaminator Washer Disinfector Critical Cleaners Will Work for You
Washer Decontaminator Washer Disinfector Critical cleaners demonstrated the ability to completely remove pathological organisms with effective repeatability. There operation is automatic, reliable, labor saving and easy to use. Central Processing departments rarely find the need to manually treat devices and report an exceptionally low rate of rejected devices.
Surgical Instrument Washer using an Ultrasonic Cleaner Solution
Conclusion
The Washer Decontaminator Washer Disinfector sequence, cold water pre-wash, ultrasonic cleaning, detergent washing action, final rinse and drying treatment of a properly designed Washer Decontaminator Washer Disinfector Critical Cleaner will provide critical cleaning, the prerequisite for safe handling, optimal disinfecting, and sterilizing of medical devices.
The UPS-1 Surgical Instrument Cleaner with Conditioners delivers; Protease Surgical Instrument Cleaning Enzymes to breakdown proteins including blood, Amylase Surgical Instrument Cleaning Enzymes to breakdown starch and catalyze the hydrolysis of starch, Lipase Surgical Instrument Cleaning Enzymes to breakdown fats and high level lipids, and Carbohydrase Surgical Instrument Cleaning Enzymes to breakdown complex starches. Enzyme Detergents that do not offer these 4 enzymes cannot remove all forms of proteinaceous bioburden and will be as effective for cleaning surgical instruments.
evaluation of Washer Decontaminators Washer Disinfectors confirmed that the efficacy of disinfection was 100%. All surgical instruments and utensils tested were sterile at the completion of the process. Surgical Instrument Washers using a four enzyme detergent cleaning concentrate Provide the Prerequisite for Sterilizing Surgical Instruments and Utensils.
NOTE: The Surgical Instrument Washers represented were manufactured by CESCO, Mercersburg PA. Although these Surgical Instrument Washer using an Ultrasonic Cleaner Solution are not currently available, the studies demonstrate the propensity for a properly designed Surgical Instrument Washer to deliver optimal results. The Cleaning Concentrates used in these studies are currently available in the form of the all-in-ONE combination enzyme detergent cleaners. A critical component for optimal cleaning is using the best possible cleaning concentrate. Recent European studies have illustrated and concluded that combination enzyme detergent cleaning concentrates are more effective than conventional cleaners. The research was initiated to deactivate prions within the objective to prevent CJD (Creutzfeldt-Jakob Disease). Surgical Instrument Washer using an Ultrasonic Cleaner Solution
ABSTRACT
Paper accepted for presentation at APIC:
Eighteenth Annual Conference and International Meeting
Nashville Tennessee
Surgical Instrument Washer using an Ultrasonic Cleaner Solution
Oral Presentation
Validation of the microbial safety of surgical instruments and utensils following automated cleaning by a properly designed Washer Decontaminator Washer Disinfector – Thermal Disinfection. A. Drake, RN and L. Ayers, MD., The Ohio State University Hospitals, Columbus, Ohio, 43210
Surgical Instrument Washer using an Ultrasonic Cleaner Solution
The application of universal precautions to instruments/utensils handling became an issue in the selection of replacement decontamination equipment for Central Sterile supply at our hospital. The new technology of an automated thermal disinfection Washer Decontaminator Washer Disinfector (TW)(CESCO TM, Mercersburg, Pa.) offered increased protection to our reprocessing staff due to decreased handling but raised concerns about the efficacy of thermal disinfection as opposed to traditional washer sterilization. Because of the limited scientific documentation of this new technology, a study was undertaken to establish the microbial safety of finished products and to identify any feature or function failure which could adversely affect outcome. The sequential functions of the Washer Decontaminator Washer Disinfector progress from flush/rinse, sonic bath, wash, rinse, lubricant/deionized water (DI) sprays to drying at 240° F. for 4 minutes. The Washer Decontaminator Washer Disinfector was challenged with selected instruments and utensils that are considered to be very difficult to clean. Included were 30 each of stainless steel non-perforating towel clips and stainless steel and glass medicine cups. Each item was rinsed with a 10 5ml suspension of Staphylococcus aureus, Pseudomonsaeruginosa, Enterococcus fecalis and Candida albicans in nutrient media and then dried. The instruments wee processed in the Washer Decontaminator Washer Disinfector 3 separate loads during times of high volume operation. All products were tested for sterility. Ten separate cultures were taken of the final rinse solution of instrument lubricant and de-ionized water prior to the drying cycle. A separate culture was taken of the instrument lubricant fluid. All instruments and utensils tested were sterile at the completion of the process. The final rinse, however, was heavily contaminated with the saprophytic bacteria Flavobacterium sp., Pseudomonas (P.) picketti and P. rubrisubalbicans. The source of the contamination was determined to be resin gel in the DI tank and not the instrument lubricant. The contamination can be eliminated by the addition of a 0.22 u filter to the DI line. Our findings support the practice of validating all features of new technologies that may compromise the expected final outcome. The Washer Decontaminator Washer Disinfector is a valid replacement for the conventional washer-sterilizer.
Ann Drake
John Temple
Product Development
replace enzyme surgical instrument cleaners, surgical instrument cleaner chemicals, surgical instrument stain cleaners, surgical instrument surface conditioners, and instrument lubricants. The 4 Enzyme detergent surgical instrument cleaner will clean all forms of surgical soil from surgical instruments including lipids, while cleaning surgical instruments fast. Nothing cleans as fast as the 4 Enzyme Surgical Instrument Detergent. Nothing can lowers costs like the 4 Enzyme Instrument Detergent, we guarantee it.
The high level multi-tiered cleaning chemicals used in the all-in-ONE 4 Enzyme Detergent easy FOAM-it Endoscope Cleaner is designed to deliver high quality endoscope cleaning outcomes with rapid results. The all-in-one enzyme detergent endoscope cleaner will lower cleaning costs and render high quality cleaning results. Compare the all-in-ONE enzyme detergent endoscope cleaner to other endoscope cleaning products. The all-in-ONE enzyme detergent endoscope cleaner are powerful against bioburden yet safe for all rigid and flexible instrument materials. The enzyme detergent endoscope cleaners rapidly break down and removes bioburden, prevent incrustation, and protect endoscope against corrosion.
The all-in-ONE enzyme detergent endoscope cleanerand the easy FOAM-it enzyme detergent endoscope cleaner deliver long lasting hydration and immediately begin to break down blood, fat, and protein from the surface of endoscopes while maintaining and building the stain-corrosion "passive layer" protection. The enzyme detergent endoscope cleaner keeps surgical instruments moist, prevents bio-burden from drying amd encrusting onto surgical instruments, inhibits bacterial growth, applies lubricates and speeds the endoscope cleaning process. The neutral pH enzyme detergent endoscope cleaner and the easy FOAM-it enzyme detergent endoscope cleaner are safe for flexible and rigid scopes, stainless steel, tungsten carbide, aluminum, brass, plastic materials, delicate surgery micro surgical instruments, ultrasonic cleaners, and washer equipment. Compare the all-in-ONE enzyme detergent endoscope cleaner and easy FOAM-it enzyme detergent endoscope cleaner to other enzyme cleaners, detergent cleaners, and cleaning chemicals. Only the all-in-ONE enzyme detergent endoscope cleaner and easy FOAM-it enzyme detergent endoscope cleaner deliver: enzyme cleaners, detergent cleaners, lubricants for: cleaning and reprocessing endoscopes, endoscope washers, endoscope disinfectors, and ultrasonic endoscope cleaners.
- endoscope cleaning procedure,
Enzyme endoscope cleaning detergents are recommended for challenging and rapid cleaning tasks due to their ability to break soil down to a form that can be removed from surfaces that are difficult to clean, and most importantly, deliver the surfactant detergents needed to clean that bioburden from the surface of endoscopes. Enzyme detergent endoscope cleaners are recommended for cleaning endoscope that are: heavily contaminated with encrustation, the emulsification of lipid bioburden and surgical compounds.
Surgical Instruments that were cleaned in a Washer Disinfector, Surgical Instrument Washer using a 4 enzyme washer disinfector detergent: evaluation of Washer Decontaminators Washer Disinfectors confirmed that the efficacy of disinfection was 100%. All surgical instruments and utensils tested were sterile at the completion of the process. Surgical Instrument Washers using a four enzyme detergent cleaning concentrate Provide the Prerequisite for Sterilizing Surgical Instruments.
Washer Disinfector, Surgical Instrument Washer using a 4 enzyme washer disinfector detergent: evaluation of Washer Disinfectors confirmed.